Skip to content

Knife-Edge

Digital Twin Specification
Twin Code:
CF-KNED01
Twin Name:
Knife-Edge
Twin Family:
Apertures, Stops, and Arrays
Family Role:
Models a movable optical edge for beam truncation, diffraction studies, and knife-edge beam-size measurement.
Category:
Component
Type:
Function-Based
Version:
1.0
VLF Package:
Platform
Last Updated:
2026-10-03

1 Purpose

The Knife-Edge twin represents an opaque screen boundary that can be positioned across an optical beam.

Its central application is virtual knife-edge beam metrology: the edge is scanned laterally through the beam and the transmitted radiant flux is recorded as a function of edge position. From this transmission curve, the beam size can be reconstructed.

The current LightTrans feature demo Knife-Edge Beam Size Measurement reproduces this classical measurement virtually and shows agreement between the beam size reconstructed from transmitted radiant flux and the direct field evaluation.

2 Geometric Support

For an ideal edge aligned with the \(y\)-axis, one half-plane transmits the field and the opposite half-plane blocks it.

The edge can be:

  • shifted laterally to scan across the beam; and
  • rotated to change its orientation in the component plane.

A finite Edge Width can be used to represent a smooth transition instead of an infinitely sharp boundary.

3 Supported Field Operation

For an ideal edge at \(x=0\), the transmission can be written as

\[ t(x,y)= \begin{cases} 1, & x\ge 0,\\ 0, & x<0. \end{cases} \tag{1} \]

The outgoing field is therefore

\[ \mathbf E_{\mathrm{out}}(x,y) = t(x,y)\,\mathbf E_{\mathrm{in}}(x,y). \tag{2} \]

The edge position and orientation determine which part of the field is transmitted.

4 Simulation Model

A physically finite edge can be represented by a smooth transition region of width \(\Delta w_e\):

\[ t(x,y)= \begin{cases} 1, & x\ge \Delta w_e/2,\\ 0, & x<-\Delta w_e/2,\\ \text{smooth transition}, & \text{otherwise}. \end{cases} \tag{3} \]

The finite transition width controls how sharply the field is truncated and therefore how strongly the edge contributes diffraction effects.

VirtualLab Fusion handles the numerical sampling required by a sharp edge internally. The user specifies the physical edge behavior; the implementation details used to keep the calculation efficient are intentionally not part of the user-facing model.

5 Parameters Where This Sheet Adds Guidance

Edge Position
Role: Defines the lateral position of the knife edge in the component plane.
Spec-sheet insight: This is the parameter to scan for a classical knife-edge measurement. The transmitted radiant flux is evaluated for successive edge positions.
Edge Orientation
Role: Rotates the blocking boundary in the component plane.
Spec-sheet insight: Align the edge with the direction in which the beam profile should be measured. Repeating the measurement with another orientation allows different transverse directions to be investigated.
Edge Width \(\Delta w_e\)
Role: Defines the width of the smooth transition between blocked and transmitted regions.
Spec-sheet insight: Smaller values represent a sharper physical edge and can strengthen diffraction effects. Start with a physically reasonable finite width and reduce it only when the influence of sharper edges is relevant to the study.
Edge Samples \(N_e\)
Role: Defines the number of samples used to resolve the finite edge transition.
Spec-sheet insight: The internal Knife-Edge specification recommends \(N_e\ge4\), with \(N_e=4\) normally sufficient. Increase it only when a convergence check indicates that the edge transition is not adequately resolved.

Knife-Edge Beam Size Measurement

The current LightTrans feature demo Knife-Edge Beam Size Measurement provides the recommended reference workflow:

  1. Place CF-KNED01 - Knife-Edge in the plane where the beam profile should be measured.
  2. Position the edge so that the beam is initially largely transmitted.
  3. Scan the edge laterally across the beam using a parameter variation.
  4. Evaluate the transmitted radiant flux for each edge position.
  5. Build the cumulative transmission curve from the scan.
  6. Reconstruct the beam size from the measured flux curve.
  7. Compare the reconstructed result with a direct field-based beam-size evaluation when a reference is desired.

This workflow reproduces the principle of a real laboratory knife-edge measurement while keeping the measurement chain entirely inside the optical simulation.

Diffraction-Aware Edge Studies

The same twin can be used whenever the effect of a finite blocking edge on a propagated field is relevant. In this case, choose an appropriate physical Edge Width and verify convergence if very sharp edges are used.

⚠️Usage note: The Knife-Edge twin models the optical interaction with the edge. Beam-size reconstruction requires a scan of the edge position together with an evaluation of transmitted radiant flux, as demonstrated in the dedicated LightTrans feature demo.
Related Twin Main Distinction
CF-APER01 - Aperture [Elliptical, Rectangular] Defines a finite transmitting aperture rather than one blocking half-plane.
CF-APGS01 - Aperture [General Shape] Use for arbitrary aperture geometries rather than a single straight edge.
CF-STOP01 - Stop General blocking element rather than the dedicated movable knife-edge model.
CF-STOP02 - Stop [Truncation] Applies a truncation profile over a specified region.
Beam Size Detectors Provide direct field-based beam-size evaluation rather than reconstruction from a knife-edge scan.

8 Possible Replacement Twins

Possible Replacement Twin When It Replaces This Twin
CF-STOP01 / CF-STOP02 Use when a general blocking or truncation region is required and a dedicated knife-edge scan is not needed.
CF-APER01 / CF-APGS01 Use when the relevant geometry is a transmitting opening instead of a blocking edge.
Beam Size Detector Use when the beam size should be evaluated directly from the simulated field rather than reconstructed through virtual metrology.

9 Further Reading

  • Feature Demo - Knife-Edge Beam Size Measurement - published September 18, 2026.
  • VirtualLab Fusion 2026.1 release notes - CF-KNED01, Knife-Edge.
  • Internal Knife-Edge twin specification - simulation model, edge width, edge sampling, and positioning/orientation behavior.